How do I change the PG PC Interface?

How do I change the PG PC Interface?

In the SIMATIC Manager you open the “Set PG/PC interface…” dialog by going to “Options > Set PG/PC interface…” and select the desired interface in the “Interface parameters used” list.

What is set PG PC Interface?

Set PG/PC Interface allows you toconfigure the communication between the PG/PC and the PLC / Drives / HMIs / other Siemens devices. Using this we select the actual communication hardware and the protocol using which various Siemens Softwares will communicate with PLCs and other devices.

What is TIA Interface?

Totally Integrated Automation Portal (TIA Portal) gives you unrestricted access to the complete range of digitalized automation services, from digital planning to integrated engineering and transparent operation.

What is PG Siemens?

SIMATIC Field PG – Ready to use For mobile operations in industrial plants, the SIMATIC Field PG offers both rugged hardware and pre-installed TIA Portal engineering software for fast and efficient configuring, commissioning, service and maintenance.

What is PC and PG?

Industrial PCs (PC) and Programmiergeräten (PG) are computers and laptops that are used in industrial, automated environments. Industrial PCs and PGs consist of specific configurations with associated software and licences, both for Microsoft and specific software.

What is PN IE interface?

Open IE communication via integrated PN/IE interface of the CPUs. A program-controlled communication procedure called Open User Communication (OUC) is used for open IE communication via the integrated PN/IE interface. Instructions in the user program control: Establishment of connections. Disconnection of connections.

What is the difference between Step 7 and TIA Portal?

TIA Portal is new software platform for configure and program S7-300/400/1200/1500. STEP 7 is only applicable to S7-300/400. TIA Portal doesn’t support all hardware in range of STEP 7 specifically old S7-300/400 modules . Note,S7-400H is not supported by current TIA versions.

How much does TIA portal cost?

Only $14.99 per month!

What is PG communication?

PG/OP communication is used to download programs and configuration data, to perform testing and diagnostics functions as well as for operator control and monitoring of a system via OPs. The CP functions as an “S7 communication relay”, that passes on the communication on PROFIBUS.

How do I connect my Siemens PLC to my laptop?

Setting up communication between PC and PLC (PPI)

  1. Connect the PPI cable between your computer and the PLC.
  2. Open the Communications dialog in STEP 7-Micro/WIN.
  3. Click on Set PG/PC Interface.
  4. Select PC/PPI cable (PPI) interface.
  5. Open the Local Connection tab and choose the port to which the cable is connected.

What’s the meaning of PG?

parental guidance
parental guidance: a rating assigned to a movie by the Motion Picture Association of America indicating that children of all ages may attend but that some material may be deemed unsuitable and that parental guidance is advised. Compare G3, NC-17, PG-13, R3.

How do I find the IP address of my S7-1200?

To figure out the IP address of your S7-1200 PLC, highlight your S7-1200 PLC in the project tree. Browse the menu bar for “Online > Extended download to device…” and check the “Show all accessible devices” check box. The IP address of your S7-1200 PLC is listed in the “address” column.

How to add a CPU to SIMATIC s7-1200?

Connect the PLC to the network. Create a new project in TIA Portal. Select Configure a device. Click on Add new device . From the controllers tree expand SIMATIC S7-1200 > CPU > Unspecified CPU 1200, select the CPU under it and click on Add.

How do I connect my s7-1200 to my plc?

Open the driver Configuration Panel by clicking on CONFIGURATION. Make sure S7-1200 is selected on the Model drop-down list and insert the PLC’s IP address into the Host field. Press Esc to return to the main driver window. Now click on CONNECT to connect to the PLC.

How to add SIMATIC s7-1200 to Tia portal?

Connect the PLC to the network. Create a new project in TIA Portal. Select Configure a device. Click on Add new device . From the controllers tree expand SIMATIC S7-1200 > CPU > Unspecified CPU 1200, select the CPU under it and click on Add. You are now on TIA Portal’s Project View .

How to set up factory I / O on s7-1200 / 1500?

The detected PLC is now on the Device view. Some of its properties need to be tweaked to allow communication with Factory I/O. Double Left-click on the controller to open the Properties panel. Start by assigning the PLC an IP address. On the General tab of the Properties page expand PROFINET interface and select Ethernet addresses.

https://www.youtube.com/watch?v=Yotb03NvRlw